FEATURES

1   Mini Size Box Culvert

     (Width 450mm)

2   Standard Size Box Culvert

     (Width from 600mm to 1800mm)

3   Supersize Box Culvert

     (Width from 2100mm to 3600mm)

​​————————————————————————

Type available:

a   Comes with dry weather flow (c/w dwf);

b   Without dry weather flow (w/o dwf)

DESIGN CONSIDERATION OF BOX CULVERT

Cracked Concrete Wall

Proof Load Test

[SVC] standard size box culvert  are comply with proof load test of 112.5 kN over an area of 320mm x 320mm placed at any position on the culvert's lid.

Cracked Concrete Wall

Custom Design

Kindly contact our Technical Personnel for assistance if custom/ special design is required.

Cracked Concrete Wall

Earth Lateral Pressure 

Coefficient of the earth lateral pressure at rest = 0.5

Bulk Density of Soil

19 kN/ m³

Cracked Concrete Wall

Backfill & Live Load

All [SVC] standard design box culvert are cater for backfill superimposed dead load NOT EXCEEDING 2.0 meter plus 45 units HB vehicle primary live loads.

Cracked Concrete Wall

Design of load requirement in accordance to

(i) BS 5400: Part 2 modified by (ii)

(ii) Department Standard BD 31/01 Buried Concrete Box Type Structure issued by Department of Transport (UK)- Highway and Traffic

(iii) JKR LTAL (Long Term Axle Load) and SV (Special Vehicle) requirements

Cracked Concrete Wall

Concrete Strength

35 to 40 N/mm2 at 28 days

Mini Size = 25mm
Standard Size = 25mm
Supersize = 30mm

Concrete Cover

Center Gradient Transparent