top of page

L SHAPE

[SVC]

FEATURES

​Available in various height & width with

standard length of 1000mm, categorized as following:

1   Drain System     

     Type 1 & Type 2

2   Retaining Wall

     Type 3(a) & 3(b)

​​————————————————————————

Application:

Retaining Wall, Open Drain, Storage Wall,

Fence Wall & etc

Advantages over cast in-situ structures:

1    Easily assembled or dismantled

2    Reliable factory cast concrete

3    Maintenance eliminated

4    Can be off loaded from transport & erected in one operation

DESIGN CONSIDERATION OF L SHAPE

Cracked Concrete Wall

35 to 40 N/mm2 at 28 days

Concrete Strength

Cracked Concrete Wall

Minimum concrete cover to reinforcement= 25mm

Concrete Cover

Cracked Concrete Wall

Earth Lateral Pressure 

Coefficient of the earth lateral pressure at rest = 0.333

Bulk Density of Soil

19 kN/ m³

Cracked Concrete Wall

Angle of Internal Friction

∠30°

Cracked Concrete Wall

Capping Beam

Standard design of L-Shape unit is catered for a maximum height of 150mm in-situ capping.

Cracked Concrete Wall

Custom Design

L-Shape unit is usually designed to suit or to fulfill the site loading condition & requirement, kindly contact our Technician Personnel for further assistance.